Before assuming your AlphaESS SMILE battery has failed, rule out a lost network connection and settings that change how it behaves, such as a high Backup Reserve or a scheduled grid charge. Genuine faults show up as a red SYS light on the inverter, or as a fault status in the app or web portal. Check three things first: whether the AlphaESS app home page says Online or Offline, the colour of the SYS and BAT lights on the inverter, and your Backup Reserve and work mode under Settings.
Safety first
AlphaESS's installation manuals describe the battery as not user-serviceable because of the high voltage inside, and say plainly: do not open the system. The inverter's case can also get extremely hot in operation, so don't touch it.
Treat any of these as an emergency rather than a troubleshooting job: smoke, flames, a burning or chemical smell, hissing or popping, a swollen or leaking battery, unusual heat, physical damage, or water around the equipment. Keep people and pets well back and don't touch anything.
AlphaESS's own emergency guidance says:
- If the battery is on fire, do not try to put it out. Evacuate everyone straight away and call 000. A burning battery gives off poisonous gases, and batteries heated above 150 °C may explode.
- If any part of the battery, inverter or wiring is under water, stay out of the water and don't touch anything. Don't use a battery that has been submerged again; contact an accredited service engineer.
- If you touch electrolyte, wash skin thoroughly with soap, rinse eyes with running water for 15 minutes, leave the area if you breathed fumes, and get medical attention.
AlphaESS's Australian warranty also asks owners not to attempt repairs when there is smoke, a burning smell, water ingress, damage or overheating, and to have the system made safe by a suitably qualified person. If you need to shut the system down, use the shutdown procedure posted near your battery system, as Energy Safe Victoria advises. Our guide to battery noise, heat and smells covers other warning signs.
Before you start: quick checks
- App status. The home page shows Online, Offline, or Partially Online when only some devices have dropped out. An Offline banner with a Reconnect button means the app has lost its connection to the system.
- Inverter lights. On SMILE-G3 and SMILE-M5 inverters, white SYS means the system is working and red SYS means a fault. A white BAT light means the battery is working, and no BAT light means a battery fault.
- Grid supply. If the METER light flashes while SYS is white, the system is in UPS (backup) mode.
- Settings. Check Backup Reserve, the work mode, and whether a VPP, Force Charge or SOC calibration is running.
- Temperature and sun. AlphaESS gives 15 to 30 °C as the battery's best operating range. It also says direct sun can make the system reduce its power.
- Recent changes. A new router, a changed Wi-Fi password or a new electricity plan can explain a sudden change in behaviour.
Common problems and what to do
| Symptom | Likely cause | What you can check | When to call your installer |
|---|---|---|---|
| App shows Offline | Network dropped, router or Wi-Fi password changed | Reconnect banner, 2.4 GHz Wi-Fi | If setup still fails after the app's checks |
| Battery won't power the house at night | Backup Reserve set high, VPP control, or a schedule | Backup Reserve slider and work mode | If settings look right and it still won't discharge |
| Battery charging from the grid | Self-Consumption Plus window, SOC calibration or Force Charge | Settings and the home page status | If you didn't set any of these |
| SYS light red | Inverter, meter, battery or grid fault | Which other lights are on or flashing | If it doesn't clear by itself |
| BAT light off, SYS red | Inverter can't talk to the battery (BMS lost) | Note the light pattern | Promptly |
| Battery lights yellow | Battery protection or error state | Temperature around the battery | If it persists |
| Backup cut out during an outage | Backup loads over the limit | Turn off heavy appliances | If it trips again with light loads |
The app says Offline
AlphaESS's app help says the connection can drop because of signal interference or a power cut. Tap Reconnect on the banner to open the setup wizard. Before you start, check that the communication module's power light is on, that Bluetooth and Wi-Fi are switched on on your phone, and that you are within 5 metres of the device.
Most AlphaESS communication modules only work on 2.4 GHz Wi-Fi, so make sure that band is enabled on your router. If your router combines 2.4 and 5 GHz under one name, check that 2.4 GHz hasn't been switched off. After replacing a router or changing the password, go to Settings, Device, Network, Wi-Fi Settings.
If the app says "Unable to connect", its own fix is to unplug the Wi-Fi module from the device, wait five seconds and plug it back in firmly. Only do this if it is the plug-in module on the outside of the inverter and you can reach it without opening anything. If several tries fail, restart your router, then use Contact Support in the app or call your installer. Our guide to a battery offline in the app has more router checks.
Don't leave it offline. AlphaESS says internet access is needed for remote diagnostics, monitoring and software updates. Under its Australian warranty for systems installed from 1 July 2026, being offline for 30 days in a row, or 90 days in total, cuts the voluntary warranty to three years, unless the battery itself caused the outage.
The battery isn't powering the house at night
The Backup Reserve slider sets the lowest charge level the battery keeps for outages. AlphaESS says it is always active and applies to every work mode. Set it above 80 per cent and the app warns that the battery may rarely discharge.
Other settings can also hold the battery back. If your system is signed up to a virtual power plant (VPP), its dispatch overrides your work mode while that authorisation is in place. Time-based Scheduling can also stop discharging at a target level you set. In plain Self-Consumption mode, AlphaESS says grid power is bought only when the battery is low. See our guide to a battery not discharging at night for more.
The battery is charging from the grid
Several features pull power from the grid on purpose:
- Self-Consumption Plus charges from solar and the grid inside a set window, up to a daily cap you can adjust.
- SOC Calibration charges the battery to full at maximum power to correct the displayed level, and may draw from the grid. AlphaESS suggests running it about every 14 days.
- UPS Reserve, where offered, uses grid power to top the battery up to your Backup Reserve.
- Force Charge is a one-off charge started from Settings. Turning it off returns the system to your work mode.
If you didn't set any of these, ask your installer to check the system's settings.
No backup during a blackout
AlphaESS's backup supplies the appliances connected to the system's backup output, so check which circuits are meant to stay on. If the Backup Reserve is below 20 per cent, the app warns that there may not be enough stored energy for a long outage. Heavy appliances can overload the backup output. The SMILE5 manual says reducing the load lets the fault clear, either after a restart or by itself within five minutes. Our guide to backup not working in a blackout covers the general checks.
Error codes and alerts
AlphaESS's installation manuals pair each error number with a light pattern, and most of the fixes in them are written for installers. Your installer can also see your system in their own portal. AlphaESS emails owners an earth fault alert that includes the code. The codes below are the ones that point to something you can check or will need to report.
| Code | Name | What it usually means | What you can do |
|---|---|---|---|
| 4 | Inverter lost | Communication with the inverter dropped | Note it; AlphaESS may update the software remotely. |
| 5 | Grid meter lost | The grid-side meter isn't talking to the system | Call your installer to check the meter link. |
| 7 | BMS lost | The inverter can't reach the battery's management system | Call your installer. |
| 8 | UPS Battery Volt Low (SMILE5) | Battery low while in backup mode | Wait for grid or solar to recharge it. |
| 9 | Backup Overload (SMILE5) | Too much load on the backup output | Turn off heavy appliances. |
| 60002 | Circuit_Breaker_Open | A battery circuit breaker is off | Call your installer; don't open the battery. |
| 100000 to 100003 | Grid_OVP, Grid_UVP, Grid_OFP, Grid_UFP | Grid voltage or frequency out of range | Check for local grid problems; call your installer if it keeps happening. |
| 100007 | Insulation_fault | Possible moisture or damage on the solar side | Often clears once wet weather passes; call your installer if it repeats. |
| 100008 | GFCI_fault | Earth fault (the code in AlphaESS's earth fault email) | Call your installer. |
| 100011 | Over_Temperature | Inverter running hot | Keep the area around the inverter clear and ventilated. |
| 100027 | Battery_lose | The inverter can't see the battery | Call your installer. |
| 100043 | Output_overload | Backup loads above the limit | Reduce the load; it can clear within five minutes. |
Battery modules have their own lights. On SMILE-G3 and SMILE-M5 batteries, white lights mean normal or standby, yellow lights mean protection or an error, and all lights off means the battery is shut down. AlphaESS says high-temperature and low-temperature protection clear once the temperature returns to range. "Cell under voltage" is different: the manuals say to call service immediately. For tips on recording codes, see our guide to reading battery error codes.
Switching off and restarting
Follow the shutdown procedure posted at your installation. The power-off sequence in AlphaESS's manuals is written for qualified installers, who are told to wear protective gloves and wait five minutes after power-off, because leftover charge and heat can still shock or burn. The Australian manuals say the battery system's AC circuit breakers should be labelled "Main Switch Battery ESS Supply" and "Main Switch Battery ESS Backup", or similar, which may help you match the sign to the switches.
SMILE-M systems can have an external emergency power off (EPO) button. If yours has one, AlphaESS says you can press it in an emergency such as a fire to shut down the inverter and switch off the battery. The solar panels stay live. If a fault keeps returning after the system restarts, stop and call your installer rather than resetting it again.
Model notes: SMILE5, SMILE-G3 and SMILE-M5
- SMILE5 uses an LCD screen with four lights: red for an inverter fault, then green lights for battery charging or discharging, normal operation, and communication. Its Status menu shows Solar, Battery, Grid, UPS and Comm pages. On SMILE5 batteries, green lights flickering every three seconds show a protection code and red ones show an error.
- SMILE-G3 inverters have SYS, BAT, METER and COM lights plus five lights that approximate the battery's charge. A white COM light means the system is connected to AlphaESS's server. The SMILE-G3-BAT-3.8S battery is rated for indoor installation only.
- SMILE-M5 uses the same four-light panel. Its batteries have a power button beside the battery circuit breaker, which installers use during start-up and shutdown.
AlphaESS has moved owners to a new app generation (version 7). If your web login stops working, AlphaESS says cloud.alphaess.com redirects to the new portal, or you can sign in at portal.alphaess.com.
When to call your installer or AlphaESS
AlphaESS's app help says to contact your installer first if your system's status looks wrong. The Australian warranty also names the original installer, the reseller or AlphaESS as the first contacts.
AlphaESS Australia's after-sales team is on 02 9000 7676 or [email protected]. Warranty claims can also go through the online complaint portal at cloud.alphaess.com/createComplaint. Under the current Australian warranty, AlphaESS may reject or limit a claim reported more than four weeks after you became aware of the problem, if the delay hurts its ability to investigate. Report problems early.
Have these ready:
- product model and serial number, and the installation address
- proof of purchase, the installation date and the installer's details
- any error numbers or light patterns, app screenshots and when the problem started
- photos of the equipment, and monitoring access if asked
AlphaESS's warranty says it sits on top of your rights under the Australian Consumer Law, and does not replace them. The ACCC's consumer guarantees page explains those rights, and our guide to battery warranty claims in Australia covers the steps. If you are thinking about adding modules, check the sizing first with our battery size calculator.
FAQ
What does Partially Online mean in the AlphaESS app?
AlphaESS uses it when some, but not all, of your devices have dropped off the network. Tap Reconnect and pick the device that is offline from the list.
Should I turn on Storm Guard in Australia?
You can, but AlphaESS says Storm Guard only uses weather alerts in EU member states and the United Kingdom. In Australia it can be switched on but will not trigger.
Sources
- AlphaESS Online Service Center: product resources (manufacturer document library, accessed November 2026)
- Installation, Operation and Maintenance Manual of SMILE-G3-S3.6/S5/B5/S6, EN (AU) V9.0 (manufacturer manual, accessed November 2026)
- Installation, Operation and Maintenance Manual of SMILE5 Energy Storage System, V2.0 (manufacturer manual, accessed November 2026)
- Installation Manual SMILE-M5, EN (AU) V2.0 (manufacturer manual, accessed November 2026)
- AlphaESS Warranty Conditions, Residential Product Series, Australia, V4.0 (manufacturer warranty, accessed November 2026)
- AlphaESS app manual: Network (manufacturer app help, accessed November 2026)
- AlphaESS app manual: Work Mode and Backup (manufacturer app help, accessed November 2026)
- AlphaESS app manual: Self-Consumption, Self-Consumption Plus and Time-based Scheduling (manufacturer app help, accessed November 2026)
- AlphaESS app manual: Advanced Settings and Storm Guard (manufacturer app help, accessed November 2026)
- AlphaESS app manual: Quick Start and During the Update (manufacturer app help, accessed November 2026)
- AlphaESS Portal for Homeowners: Home Dashboard at a Glance and Help and Support (manufacturer portal help, accessed November 2026)
- AlphaESS Australia: contact us (manufacturer's Australian office, accessed November 2026)
- Energy Safe Victoria: energy safety during bushfires (state safety regulator, accessed November 2026)
- ACCC: consumer rights and guarantees (national consumer regulator, accessed November 2026)