Before assuming a Growatt APX battery has failed, check the hybrid inverter's working mode, the data logger's internet link, and whether the battery is limiting itself because it is full, empty, hot or cold. Growatt's APX manual lists many Protect codes that clear on their own once conditions return to normal. Begin with three checks: the code on the inverter screen or in the ShinePhone app, the colour of the light on the ShineWiFi-X stick, and the charge percentage on the APX Power Module display.
Safety first
The APX is a high-voltage battery, and Growatt says only qualified, trained people may install, operate or maintain it. As an owner, you can look at the display, the lights and the app, but never open, unplug or move anything.
Growatt's emergency guidance in the APX manual is clear:
- Fire: Do not try to put it out. Get everyone away immediately, then call 000.
- Flood: If the battery has been soaked or under water, don't touch it, because of the risk of electric shock. Contact Growatt or your distributor straight away.
- Damaged case: Don't use a battery with a damaged shell. Contact Growatt or your distributor about it.
- Leaks: Keep away from leaked liquid or gas. Anyone exposed should get medical help.
When you ring 000, South Australia's Metropolitan Fire Service (MFS) asks you to say a home battery is involved. It advises following the shutdown sign near the inverter or switchboard only if that is safe, and keeping a struck, flooded or fire-affected battery off until it is inspected.
Growatt MIN XH2 inverters sold in Australia and New Zealand have an earth fault alarm switched on by default. If it trips, the red light comes on and a buzzer sounds continuously until the fault is fixed. Don't touch the system; call your installer.
Recall: Growatt SPH BL-UP hybrid inverters
Product Safety Australia published a recall on 17 November 2023 (PRA 2023/19974) for Growatt SPH3000TL BL-UP, SPH3600TL BL-UP, SPH4000TL BL-UP, SPH4600TL BL-UP, SPH5000TL BL-UP and SPH6000TL BL-UP inverters. They were sold through Go Solar and Solar Mart between 1 July 2022 and 31 October 2023. The emergency power supply (EPS) port plug can be pulled out by hand, exposing live, hazardous voltage.
If your inverter's model matches, the recall asks you to switch it off immediately and contact Growatt Australia on 1800 476 928 or [email protected]. Growatt will arrange for the EPS connector to be permanently secured and labelled. The recall page includes a serial number list you can check against your inverter's label. Never pull at the EPS plug yourself.
Before you start: quick checks
- Read the inverter. On a MIN XH2, a steady green light means normal operation, a slow green blink means standby, and steady red means a fault. A short double green blink means a warning, and a slow yellow blink means it is in programming mode.
- Read the APX display. It shows the charge level as a percentage. Its light bars fill one by one clockwise while charging and go out anticlockwise while discharging. If the display is dark, Growatt says tapping the case just below it wakes the screen.
- Check the data logger light. On a ShineWiFi-X, flashing blue means everything is connected. Other colours are explained below.
- Check the working mode. Growatt hybrid inverters run in Load First, Battery First or Grid First, with Load First as the default. Battery First and Grid First apply to set time periods.
- Rule out a blackout. Error 302 means the inverter sees no AC connection, and Error 300 means grid voltage is out of range.
- Think about temperature. The APX manual says performance may be derated below 10°C or above 45°C, and several Protect codes limit charging in heat or cold.
Common problems and what to do
| Symptom | Likely cause | What you can check | When to call the installer |
|---|---|---|---|
| Battery not charging | Little surplus solar, battery full, cold, or a Protect code | Mode, display percentage, any Protect code | An Error code appears, or charging never resumes |
| Grid power used at night | Discharge cutoff reached, Battery First or Grid First period | Mode and time periods, charge level | Battery shows charge but stays idle |
| Offline in ShinePhone | Router change, internet down, firewall | ShineWiFi-X light colour, router internet | Logger light off or steady red |
| No power in a blackout | Backup box or Backup setting missing, overload | Whether a backup box is fitted, Protect 707 | Backup has never worked |
| Red light on the battery | Power Module or battery module fault | Display, error code | Straight away for steady red |
| Buzzer, heat or smell | Earth fault alarm or battery fault | Nothing hands-on | Immediately, and 000 for smoke or fire |
Battery not charging
Growatt's hybrid inverter manuals describe Load First as solar supplying the house first, with only the surplus charging the battery. If household use is high or the day is overcast, little may reach the battery. Battery First charges the battery as a priority during a set period, up to a charging cutoff level.
A full battery also stops charging. Growatt's codes Protect 1001 and Protect 1007 mean the battery is fully charged and charging is limited, and both clear automatically. In cold weather, Protect 1015 and Protect 1088 limit the battery until it warms up. Our guide to a solar battery not charging covers causes shared by all brands.
Grid power used at night
In Load First mode, the battery powers the house until it reaches the discharge cutoff level, then the grid takes over. A Grid First period puts exporting to the grid first, with its own discharge cutoff. Protect 1003 and Protect 1009 mean the battery is empty and discharging is limited, and both recover automatically.
Your installer sets these levels and periods, so note your mode and charge level and ask them to check. Our guide to batteries not powering the home at night explains the pattern in general terms.
Offline in ShinePhone
Monitoring runs through a data logger in the inverter's USB port, such as the ShineWiFi-X. Its light shows where the connection breaks:
| Light | What it means | What to try |
|---|---|---|
| Off | Not talking to the inverter | Call your installer |
| Flashing red | Connected to the inverter only | Network setup is incomplete |
| Steady green | Can't join your home router | Check the router's name and password |
| Flashing green | On your router but can't reach Growatt's server | Check the router's internet and firewall |
| Flashing blue | Fully connected | No action needed |
| Steady red | Logger is faulty | Ask your installer to replace it |
Growatt says the logger only works on 2.4 GHz Wi-Fi. The router name should use plain letters and numbers, and networks that need a second login, such as public hotspots, won't work. If the light flashes green, check the router isn't blocking ports 5279 or 5280. Setup is done through the ShinePhone app, following Growatt's ShineWiFi-X configuration guide.
Staying online protects your warranty. Growatt's Australian APX and ARK warranties say the battery warranty drops to three years if the system isn't monitored on Growatt's platform. Our guide to a battery offline in the app has more general tips.
No power in a blackout
A MIN XH2 only supplies power during an outage when it is paired with a battery and a backup box, or Growatt's SYN unit, and the Backup setting is enabled. Growatt's manual says that with Backup disabled, the inverter will not output power when the grid fails. On three-phase systems, the APX S2 manual names the backup version of the MOD XH inverter.
If backup started but then dropped out, Protect 707 points to an overload. Growatt's advice for off-grid operation is to reduce the load in the home, and it recovers automatically after 10 minutes. Ask your installer whether backup was ever set up, and see our blackout backup guide.
Lights on the battery
The APX Power Module's status light glows steady green in normal operation and blinks green slowly in standby. A faster green blink means a protection state, and red means a fault. Each battery module also has its own bar on the display: green is normal and red signals a fault in that module.
Buzzer, heat or smell
A continuous buzzer on a MIN XH2 is the earth fault alarm described above. Growatt also recommends checking the DC switch and cables for visible damage or discolouration, and contacting your installer if you see any. Look, but don't touch.
Protect 1013 and Protect 1047 mean the battery or its surroundings are too hot, and Growatt limits charging and discharging until it cools. Keep stored items away from the battery. A burning smell, hissing or swelling calls for the emergency steps above. Our warning signs guide has more detail.
Error codes and alerts
Growatt's APX manual splits codes into Error and Protect codes for the Power Module and battery modules. Most Error code fixes involve switching breakers and restarting, which the manual reserves for qualified people.
| Code | What it means | What you can do |
|---|---|---|
| Protect 1001, Protect 1007 | Battery full, charging limited | Nothing. It clears automatically |
| Protect 1003, Protect 1009 | Battery empty, discharging limited | Nothing. It clears once the battery recharges |
| Protect 1013 | Battery too hot, output limited | Keep the area clear and let it cool |
| Protect 1015, Protect 1088 | Battery too cold, output limited | Usually clears as it warms |
| Protect 1047 | Internal temperature too high | Clears as it cools. Call if it keeps returning |
| Protect 707(0) | Overload | Off-grid: reduce load. On-grid: contact Growatt |
| Error 411(0) | Power Module and inverter not communicating | Call your installer |
| Error 502(0) | Battery module voltage low | Call your installer, who checks the monitoring data |
| Error 506(2) | Power Module fuse blown | Call your installer |
| Error 203 | Solar insulation resistance low | Don't touch anything. Call your installer |
| Error 300, Error 304 | Grid voltage or frequency out of range | Often the grid. Report repeats |
| Error 302 | No AC connection | Check for a blackout, then call your installer |
| Error 408 | Inverter over-temperature | Check ventilation. Call if it persists |
| Warning 401 | Inverter and meter not communicating | Call your installer |
The full battery list is in section 6.6 of the APX S0 user manual. Inverter codes are in the MIN XH2 manual. Our guide to reading battery error codes explains how to report them.
Restarting or shutting down
The APX manual's power-off sequence runs from the grid breaker to the inverter's DC switch, then the Power Module's DC switch. It then needs about 15 minutes for the Growatt logo to go dark. The manual warns that switching back on before shutdown has finished can damage the fuse. That is one more reason to leave restarts to your installer.
In an emergency, use the shutdown sign if it is safe. Don't cycle the system to clear a code that keeps returning.
If the system has been off for a while, act quickly. Growatt says an over-discharged battery should be recharged to 40 per cent within seven days, and the APX can only be charged through the inverter.
Model notes
- APX S0: One APX 55027-P0 Power Module with one to six APX 5.0P-B1 battery modules, paired with single-phase MIN XH or MIN XH2 inverters.
- APX S2: The same 5 kWh modules with a different Power Module, for three-phase MOD XH (backup version) or MID XH inverters.
- ARK XH and ARK LV: Earlier Growatt batteries covered by an Australian warranty. Growatt Australia's download pages list the ARK warranty but not an ARK manual, so ask your installer for the manual for your unit.
When to call your installer or Growatt
Start with your installer. Growatt's MIN XH2 manual lists what support staff need:
- the serial number and model number
- the error message shown on the display or app
- a brief description and whether you can reproduce it
- whether it has happened before
- the weather and conditions at the time
Growatt's Australian claim procedure says owners can ask Growatt Australia directly for a claim link. Growatt Australia's service line is 1800 476 928, with email and address details on its contact page. The APX warranty asks for a detailed fault description and the error code shown, so keep screenshots.
Your rights under the Australian Consumer Law sit alongside the manufacturer's warranty. The ACCC's consumer guarantees page explains them, and our warranty claims guide covers the steps.
FAQ
What is the difference between an Error code and a Protect code?
In Growatt's APX lists, Protect codes usually describe the battery limiting itself for a while, such as when it is full, empty, hot or cold. Many clear on their own. Error codes point to faults that usually need a restart or a technician.
My APX display is blank. Is something wrong?
Not necessarily. Growatt's manual says you can tap the case just below the display to wake the screen. The Growatt logo stays lit while the battery is on.
Why does my battery stop discharging with some charge left?
It has most likely reached the discharge cutoff level set for your working mode, which keeps some charge in reserve. Ask your installer if you want the level reviewed.
Sources
- APX 5.0~30.0P-S0 AU High Voltage Battery System User Manual (Growatt manufacturer manual, accessed November 2026)
- APX 5.0~30.0P-S2 AU High Voltage Battery System User Manual (Growatt manufacturer manual, accessed November 2026)
- MIN 2500-6000TL-XH2 Installation and Operation Manual (Growatt inverter manual, accessed November 2026)
- SPH 3000-6000TL-HU Series User Manual (Growatt hybrid inverter manual, working modes, accessed November 2026)
- ShineWiFi-X User Manual (Growatt data logger manual, accessed November 2026)
- Growatt Battery Warranty Card, APX HV Battery AU (Growatt warranty, accessed November 2026)
- Growatt Battery Warranty Card, ARK series, Australia (Growatt warranty, accessed November 2026)
- Growatt New Energy Australia Warranty Claim Procedure (Growatt Australia document, accessed November 2026)
- Growatt Australia FAQ and Contact us (Growatt Australia support pages, accessed November 2026)
- Growatt solar power inverters models SPH3000TL BL-UP to SPH6000TL BL-UP recall (Product Safety Australia, PRA 2023/19974, accessed November 2026)
- Photovoltaic (PV) Array and Battery Energy Storage Systems fact sheet (South Australian Metropolitan Fire Service, accessed November 2026)
- Consumer rights and guarantees (ACCC, accessed November 2026)