A SolarEdge Home Battery takes its instructions from the SolarEdge inverter it is connected to, so the inverter is the first place to look when the battery misbehaves. Start by noting the three lights on the battery and the three on the inverter, then look for an error code in the SolarEdge monitoring app, and confirm whether your system was ever set up for backup. Australian owners should also know that, according to November 2026 trade press reports, SolarEdge is closing its local operations and moving support to its international channels.
Safety first
SolarEdge says the Home Battery and its parts are not user-serviceable, and that it must not be opened, repaired or modified. Its emergency response guide explains the risk plainly: a damaged battery can still hold a dangerous high voltage, even when it seems flat.
Signs SolarEdge treats as an emergency
SolarEdge's emergency guide names smoke as the most obvious sign that cells inside are overheating out of control. Loud banging from the battery, or heat coming off it, are other signs. If you notice any of them:
- If you can do it without going near smoke, switch the battery off. SolarEdge's guide says to turn its ON/OFF/P switch off and switch off its DC circuit breaker, or follow the shutdown sign at your switchboard.
- Leave the area and keep everyone else away.
- Call 000 and say a lithium-ion home battery is involved.
SolarEdge warns that smoke from a venting battery is likely to be flammable and may ignite, and that an extinguished lithium-ion fire can reignite. Leave firefighting to the fire service.
Leaks, smells and damage
Electrolyte leaking from damaged cells is colourless with a sweet smell, and it is flammable and corrosive. If you notice that smell, SolarEdge says to clear the area and ventilate it, and to avoid touching any liquid.
SolarEdge also says to handle a battery that has stopped working with caution, because its charge level and risk of venting may be unknown. Don't try to move or remove a damaged or failed battery. South Australia's Metropolitan Fire Service adds that any battery affected by impact, fire, an electrical event or water must stay out of service until it has been inspected, even if it appears to work.
SolarEdge has left Australia: what it means for owners
In November 2026, pv magazine Australia, ESS News and PV Tech reported that SolarEdge had told installers it was ending its direct sales and operations in Australia, with final orders due by 20 November 2026. Both reports say warranty coverage continues, and that technical support now runs through SolarEdge's international call centre and online self-service portal. This guide could not find a public SolarEdge statement confirming the details, so check them with your installer.
Your legal rights don't depend on a local office. The ACCC explains that manufacturers and importers must keep spare parts and repair facilities available for a reasonable time after purchase, unless you were told otherwise when you bought. It also says consumer guarantees can't be taken away by anything a business says or does. Keep your installation paperwork and monitoring login somewhere easy to find.
Quick checks before you call
- Battery lights. A blinking Power light means charging or discharging, and a steady Comm light means its network link is working.
- Inverter lights. Blue on means the inverter is talking to SolarEdge's monitoring platform. Green on means it is producing, and a brief green flicker every few seconds at night is normal night mode. Red means a system error.
- The app. SolarEdge shows errors as codes in its monitoring platform. Write the code down exactly.
- Your internet. Check the router works and that another device can get online.
- Backup setup. SolarEdge's Australian guides say backup needs a Home Hub inverter and a SolarEdge Backup Interface, and that the backup function is off by default.
- Energy mode. Find out whether your installer set Maximum Self Consumption, a Time of Use charge and discharge profile, or Backup only.
- Temperature. SolarEdge rates the battery to charge between minus 10°C and 50°C, and warns that long periods at extreme temperatures may affect warranty cover.
Common problems and what to do
| Symptom | Likely cause | What you can check | When to call the installer |
|---|---|---|---|
| Battery stuck below 10% while solar is producing | Battery not charging, or a fault | Inverter and battery lights, error code | Straight away; SolarEdge lists a battery self-test for this |
| Battery idle at night | Reserve level, Time of Use profile, or Backup only mode | Energy mode in the app | It stays idle above the reserve in MSC mode |
| No power in a blackout | Backup not enabled, no Backup Interface, or tripped circuits | Backed-up circuit breakers, Backup Interface light | Backup has never worked |
| Inverter red light | System error | Error code in the app | Straight away |
| Battery Fault light on | Battery fault | Which other lights are on | Straight away |
| Monitoring offline | Internet or router problem | Router, other devices, recent changes | Internet works but data stays missing |
| Inverter won't turn on | External shutdown switch is off | The switch position | If the switch is on and it still won't start |
Battery not charging or running flat
Because the inverter manages the battery, check the inverter's lights and error code first. SolarEdge's 2025 quick guide says that if the inverter is off or in a fault state, the battery should be turned off to protect its lifespan, so an inverter fault is worth reporting quickly rather than leaving for weeks.
SolarEdge's Australian troubleshooting table covers a battery that sits below 10% and keeps discharging without charging while solar is producing. The fix starts with a battery self-test that your installer runs in SolarEdge's installer app. If the battery passes, the installer contacts SolarEdge support. Our general guide to a battery not charging covers checks for any brand.
Not powering the home at night
SolarEdge's Australian configuration guide describes three ways to use the battery. Maximum Self Consumption (MSC) uses stored energy in the home, with a level of energy reserved for backup. Time of Use follows a charge and discharge profile your installer sets. Backup only keeps the stored energy purely for outages, so a battery set this way won't power the home at night, by design.
If you're unsure which mode you have, ask your installer to confirm it and the reserve level. The battery not powering the home at night guide explains how reserve settings work in general.
No backup during a blackout
SolarEdge's Australian datasheet says backup needs a SolarEdge Home Hub inverter and a SolarEdge Home Backup Interface. Its configuration guide adds that the backup function is disabled by default. Without it, the battery still works day to day but won't power your circuits in an outage. The same guide describes the Backup Interface connection for the single-phase Home Hub only, so if your battery is on a three-phase SolarEdge inverter, ask your installer whether backup was ever part of the design.
When everything is set up, the Backup Interface detects the outage and the inverter switches to backup in about three seconds. If backup should work but doesn't, SolarEdge's Australian troubleshooting list is: the inverter is producing, backup is enabled, no errors are showing, the backed-up circuit breakers are on, and the green light on the Backup Interface is steadily lit, which means backup mode. You can check the breakers and lights you can see without opening anything; leave the settings to your installer. More general steps are in backup not working in a blackout.
Monitoring offline
If the monitoring app stops updating, SolarEdge's guide suggests some simple checks. Make sure the modem or router works, test the internet with a laptop or phone on the same network, and look for a firewall or network filter that might block the inverter. For Wi-Fi, the username and password must match your router.
Your installer can see more on the inverter's status screen, such as "LAN cable disconnected", "No DHCP", "Gateway not responding" or "No Internet connection". See battery offline in the app for router tips that suit any system.
What the lights mean
The battery has three lights, labelled Power, Comm and Fault.
| Battery light | Meaning |
|---|---|
| Power blinking | Charging or discharging |
| Power flickering | Standby, or DC pairing |
| Comm on | Network communication working |
| Comm blinking | Searching for the network |
| Fault on | Fault |
| Fault blinking fast | Firmware update |
| All three on | Booting or resetting |
The Home Hub inverter's three lights are red, green and blue.
| Inverter lights | Meaning |
|---|---|
| Green on | Producing power |
| Green blinking, switch on | AC connected but not producing |
| Green flickering | Night mode, no production |
| Green blinking, switch off | Inverter off and DC voltage at a safe level |
| Red and green blinking, switch off | Inverter off but DC voltage not yet safe |
| All three alternating | Firmware upgrade, which can take up to five minutes |
| All three on | Configuration or reboot |
| Red on | Error |
| Blue on | Connected to SolarEdge monitoring |
When the red light shows an error, an installer can use the inverter switch to display the type: arc detected, an isolation or RCD problem, a grid error, high temperature, pairing failure, or another issue.
Error codes to know
SolarEdge's Australian Home Hub guide lists two battery error codes, and points installers to a separate SolarEdge document for the full list.
| Code or symptom | What it means | What happens next |
|---|---|---|
| Error 3x6B | Battery communication error | Installer checks the communication wiring and battery configuration |
| Error 3x6C | Battery internal error | Installer contacts SolarEdge support |
| Battery self-test failed | Wrong battery connections | Installer checks the DC and communication cables |
| Inverter won't turn on | External shutdown switch is off | Find out why the switch was turned off before turning it back ON |
For reading codes from other brands, see battery error codes explained.
Shutting down and restarting safely
Australian battery installations should display a site-specific shutdown procedure near the inverter, which the Clean Energy Regulator's inspectors check for. That sign is written for your installation, so it comes first.
SolarEdge's Australian configuration guide gives this general shutdown order:
- Turn the inverter's switch to OFF and wait until the green light blinks, which means the DC voltage is safe, or wait five minutes.
- Switch off the AC supply to the inverter at its isolator, if fitted, and at the main switchboard.
- Switch off the DC isolator on the inverter, and on the DC combiner if there is one.
- Turn the battery's switch to OFF, then switch off its circuit breaker.
The start-up order in the same guide begins with the battery's breaker and switch. After a fault, let your installer decide when to restart rather than cycling the system yourself. The inverter switch also has a P position, which installers use for pairing and setup; leave that position alone unless your installer is guiding you.
When to call your installer or SolarEdge
Call your installer first. They can read the inverter's status screens, run the battery self-test and take the fault to SolarEdge. SolarEdge's quick guide lists SolarEdge support for technical issues.
Before you call, gather:
- the battery model (BAT-10K1P for the Australian Home Battery) and the serial numbers of the battery and inverter
- any error code from the app, and the lights on both the battery and inverter
- screenshots of the monitoring graphs from when the problem started
- whether backup has ever worked at your home
If the installer has closed or won't help, the consumer guarantees still apply. Our guide to battery warranty claims in Australia explains the steps.
FAQ
Is my Energy Bank the same as a SolarEdge Home Battery?
Yes. SolarEdge's own documents page lists the Energy Bank as model BAT-10K1P under the SolarEdge Home Battery name, and its emergency guide records the name change to Home Battery (High Voltage) in 2022.
Is my SolarEdge battery still under warranty now SolarEdge has left Australia?
Trade press reports say warranty coverage continues, with support from SolarEdge's international team. Your consumer guarantee rights under Australian law also remain.
Why does my battery stay full during the evening?
It may be set to Backup only, which keeps the energy for outages. Ask your installer which mode and reserve level your system uses.
Sources
- SolarEdge Home Battery for Australia datasheet, BAT-10K1P (2022) (manufacturer datasheet, accessed November 2026)
- SolarEdge Home Battery for Australia datasheet, BAT-10K1P (December 2024 edition) (manufacturer datasheet, copy hosted by Australian distributor AC Solar Warehouse, accessed November 2026)
- Installation Guide: SolarEdge Home Hub Inverter Single Phase for Australia, version 1.5 (manufacturer manual MAN-01-00812-1.5, copy hosted by AC Solar Warehouse, accessed November 2026)
- SolarEdge Solution Connection and Configuration Guide for Australia, version 6.0 (manufacturer guide, May 2024, copy hosted by AC Solar Warehouse, accessed November 2026)
- SolarEdge Home Battery (High Voltage) Installation and Operation Guide, version 1.5, North America and Australia (manufacturer guide, March 2022, copy hosted by distributor Segen, accessed November 2026)
- SolarEdge Home Battery 400V Quick Installation Guide, version 1.1 (manufacturer guide, North American edition, January 2025, copy hosted by RES Supply, accessed November 2026)
- SolarEdge Home Battery (High Voltage) Emergency Response Guide, version 2.1 (manufacturer safety document, March 2022, copy hosted by RES Supply, accessed November 2026)
- Energy Bank: certification and documents (manufacturer documents page, UK, accessed November 2026)
- SolarEdge exits Australian market (pv magazine Australia, 9 November 2026, accessed November 2026)
- SolarEdge exits Australian market (ESS News, 9 November 2026, accessed November 2026)
- SolarEdge ends direct solar sales in Australia and New Zealand (PV Tech, November 2026, accessed November 2026)
- Consumer rights and guarantees (ACCC, accessed November 2026)
- Solar battery inspection checklist (Clean Energy Regulator, current as of 21 January 2026, accessed November 2026)
- Photovoltaic (PV) Array and Battery Energy Storage Systems fact sheet (South Australian Metropolitan Fire Service, accessed November 2026)