Battery error codes look cryptic, but most belong to a handful of families: problems with the grid supply, temperature, communication between parts of the system, the battery itself, or wiring and insulation. Grid and temperature alerts often clear on their own once conditions return to normal. Communication, battery and wiring faults usually need your installer. Your job as the owner is to read the alert, write it down with the time and the light pattern, check the simple things the manufacturer allows, and pass it on. Codes differ between brands and even between models, so always check your own manual's list.
Safety first when an alert appears
An alert on its own is not an emergency. An alert together with smoke, a burning or chemical smell, hissing or popping, swelling, leaking or a very hot unit is. In that case leave the area, call 000 if there is smoke or fire, and follow our warning signs guide.
Some codes point to electrical faults that only an electrician should touch, such as insulation, earth and arc faults. Sungrow's manual tells service staff not to open the inverter at all if there is an odour, smoke or abnormal appearance. It also says to restart the inverter only after any fault that affects safety has been removed. For owners, that means don't clear or reset a fault again and again to make it go away. Note it, leave the equipment closed and call your installer.
Where codes and alerts show up
- In the app. Most brands push alerts to their app. Sungrow says faults appear in its app, and on the inverter screen for models that have one.
- On the inverter screen. On Sungrow's SH-RS hybrid inverters, touching the indicator shows the error codes when the inverter is in an error state. The screen turns off after five minutes without use.
- As light colours or patterns. Tesla Powerwall and Enphase IQ Battery mainly use coloured lights. BYD's Battery-Box uses a counted sequence of white and blue flashes for its event codes.
Not every alert means a fault
Manufacturers grade their messages. Sungrow separates "alarms" from "faults". For many of its system alarms the inverter can keep running while the cause is checked. System faults are more serious: Sungrow's steps start with waiting for the inverter to recover, then a switch-off and restart sequence, then a call to Sungrow. Ask your installer before attempting any restart sequence.
For grid-related faults, Sungrow says the inverter generally reconnects by itself once the grid returns to normal. Grid alerts become a concern when they repeat.
Enphase's battery lights show the same idea. A solid yellow light means the battery has paused because of high temperature, while a red double flash means an error state that needs Enphase Support.
The main families of alerts
The examples below come from Sungrow's hybrid inverter manual, with Tesla, Enphase and BYD examples where they apply. They are summaries in our own words; check the full list in your manual before acting.
| Family | Example from official documentation | What it usually means | What you can do | Installer needed? |
|---|---|---|---|---|
| Grid voltage or frequency | Sungrow grid overvoltage (alarm IDs 2, 3, 14, 15), undervoltage (4, 5), over or under frequency (8, 9) | Grid supply outside the inverter's set limits | Wait; it usually reconnects when the grid settles | If it repeats often |
| Grid outage | Sungrow grid power outage (10) | No grid supply detected | Check whether the street has power | If the grid is fine but the alert stays |
| Temperature | Sungrow high ambient temperature (37), low ambient temperature (43); Enphase solid yellow light | Too hot or too cold to run normally | Keep vents and surroundings clear | If it doesn't clear when the weather eases |
| Communication | Sungrow BMS communication fault (714), meter communication alarm (514); Enphase "Batteries not reporting" | Parts of the system have stopped talking | Wait 15 to 20 minutes for Enphase alerts | If it persists |
| Battery | Sungrow battery alarm and battery fault groups; BYD event codes; Enphase red double flash | Battery or its management system has a problem | Note the code and light pattern | Yes |
| Leakage or insulation | Sungrow excess leakage current (12), low system insulation resistance (39) | Moisture or damaged cabling | Note whether it was damp or raining | If it repeats in fine weather |
| Arc or earth fault | Sungrow electric arc fault (88), grounding cable fault (106) | Possible damaged cable or loose connection | Leave the equipment closed | Yes, promptly |
| Backup overload | Sungrow off-grid load overpower fault (51) | Too much load on backup circuits | Switch off large appliances | If small loads trigger it |
| Meter or CT wiring | Sungrow meter/CT reverse connection alarm (84) | Sensor fitted or wired incorrectly | Note when it started | Yes |
| Inverter fault | Tesla Powerwall 3 flashing red light | Fault in the battery's built-in inverter | Note it and check the app | Yes |
Grid alerts
Grid alerts are common and usually about the electricity network, not your battery. Sungrow says the inverter normally reconnects once the grid returns to normal. If a grid voltage alert keeps repeating, its steps involve measuring the actual grid voltage and checking the inverter's protection settings. Any changes to those settings need the network operator's consent. That is work for your installer, who may involve your local network company.
Temperature alerts
Sungrow says its inverter generally resumes once the temperature returns to normal, and that battery temperature alarms usually recover by themselves too. Persistent heat alerts point to ventilation or direct sun. Tesla notes Powerwall may limit charging and discharging at temperature extremes. If temperature alerts are frequent, our not charging guide covers what you can safely check.
Communication alerts
The battery, inverter, meter and gateway all need to exchange data. Enphase says its system usually recovers from "Batteries not reporting" or "Microinverters not reporting" within 15 to 20 minutes, and to contact Enphase Support if it doesn't. BYD notes that a Battery-Box shuts down within 30 minutes if it loses contact with the inverter. An app that says "offline" is a different issue, covered in our offline battery guide.
Battery faults
For Sungrow's battery fault group, the manual's steps start with checking the battery power cable connections and the battery's voltage. Those are electrical checks for your installer, who will contact the battery maker if needed. BYD's service guideline says most of its event codes come from faulty communication, incorrect app setup or a missed restart after setup. Codes in the EC 203 to EC 803 range mean a module isn't being recognised, with the first digit pointing to the affected module.
Reading warning lights
| Brand | Normal | Needs attention |
|---|---|---|
| Tesla Powerwall 2 | Solid (idle) or fading (charging or discharging) | Flashing means a fault is present |
| Tesla Powerwall 3 | Solid white (normal), flashing white (idle) | Flashing red means an inverter fault |
| Enphase IQ Battery 5P | Solid or pulsing green or blue | Solid yellow (high temperature), red double flash (error) |
| Sungrow SH-RS inverter | Blue on (normal), blue flashing (standby or start-up) | Red on means a system fault |
| BYD Battery-Box | Steady white (standby), blinking white (charging or discharging) | Blue flashing once a second means an event code |
To read a BYD event code, BYD's guideline says to start counting when the white light begins to flash, then count the white flashes and the blue flashes. One white flash followed by three blue flashes is EC 103, for example. White and blue flashing every half second during start-up is normal.
Codes that can mislead
Some alerts don't mean what they seem.
- BYD warns that if the battery isn't correctly configured in its app, the event code can be misleading.
- Sungrow says that if the communication cable between the inverter and battery isn't connected correctly at installation, the battery may not work properly or its information may not appear on the inverter.
- After a software update, Sungrow says the inverter, communication module and battery software should be upgraded together. Mismatched versions can cause problems, so contact your installer if anything looks wrong afterwards.
- Sungrow also notes that its manual covers all its hybrid models, so your inverter may show only some of the listed codes.
What to write down before you call
Installers and manufacturers ask for much the same details. Sungrow wants the model, serial number, fault code or name and a short description.
Tesla asks for owner contact details, Powerwall and Gateway serial numbers and a brief description. Enphase says its support staff will ask about the light status on the battery and the IQ System Controller. BYD's warranty claim form asks for firmware versions, inverter details and the working mode. Gather:
- the exact code number and name, as shown
- the light colour and pattern on each unit (a short video helps)
- the date and time it first appeared, and how often since
- the weather, and anything else happening (a blackout, a big appliance starting, recent electrical work)
- screenshots of the app's alert history and power flow
- model, serial and firmware numbers if the app shows them
When to call your installer or the manufacturer's support line
Call your installer for any battery, communication, wiring, insulation, arc or earth fault, and for grid or temperature alerts that keep coming back. Start with the installer or retailer; Sungrow's manual says to contact the dealer first, then Sungrow if the dealer can't solve it. Brand specifics are in our guides for Tesla Powerwall, Enphase IQ Battery, Sungrow and BYD Battery-Box.
If the code turns out to be a product defect, the ACCC says your consumer guarantee rights apply as well as the manufacturer's warranty, and the business that sold it can't send you away to the manufacturer. Our warranty claims guide explains the process.
FAQ
Can I clear a fault code myself?
Only if your manufacturer documents an owner step for it. Many faults need an electrical check first. Clearing a code repeatedly can hide a problem, so record it and call your installer.
Should I worry about grid overvoltage alerts?
An occasional one is usually the grid, and the inverter reconnects when things settle. If they happen often, your installer can check the voltage and settings with your network company.
Where do I find the full code list?
In your inverter or battery manual, usually in a troubleshooting chapter. Your installer can also give you the correct manual for your exact model.
Sources
- 1-phase Hybrid Inverter SH3.0RS to SH6.0RS-20 User Manual (Sungrow inverter manual, troubleshooting chapter, accessed November 2026)
- High Voltage LFP Battery SBR064/096/128/160/192/224/256 User Manual (Sungrow battery manual, accessed November 2026)
- Enphase Energy System with IQ Battery 5P Owner's Guide (Enphase owner's guide, Australian site, accessed November 2026)
- Powerwall 2 Owner's Manual: Troubleshooting (Tesla owner manual, Australian edition, accessed November 2026)
- Powerwall 2 Owner's Manual: Technical Support (Tesla owner manual, Australian edition, accessed November 2026)
- Powerwall 3 Owner's Manual: Troubleshooting (Tesla owner manual, EMEA/APAC edition, accessed November 2026)
- Powerwall 2 Owner's Manual: Care and Maintenance (Tesla owner manual, Australian edition, accessed November 2026)
- BYD Battery-Box Premium HVS&HVM Service Guideline and Checklist for BCU-V2.0 (BYD service guideline, accessed November 2026)
- BYD Battery-Box Premium Limited Warranty, HVS and HVM, Australia (BYD warranty, accessed November 2026)
- Repair, replace, refund, cancel (ACCC consumer guidance, accessed November 2026)