When a battery's charge falls overnight even though "nothing is on", the energy has often gone somewhere you can trace: fridges, standby appliances, hot water or air conditioning running on timers, a virtual power plant (VPP) event, or a schedule set up for your tariff. A sudden jump in the percentage, up or down, is often the battery correcting its own estimate of how full it is. If the battery was truly idle and the charge still fell, that needs your installer. Start with the app's energy history for the night in question, then check for VPP or schedule activity, then note whether the jump happened near full or near empty.
Safety first
Falling charge is rarely a safety issue by itself. It is one if the battery also feels unusually hot, smells of burning or chemicals, looks swollen or is leaking, or makes hissing or popping sounds. Then stop, keep everyone away and follow our warning signs guide, calling 000 for smoke or fire.
Some batteries are being drained on purpose for safety. Product Safety Australia's recall notice for some Tesla Powerwall 2 units says most affected units have been remotely discharged by Tesla to lower an overheating risk until they are replaced. If you own a Powerwall 2 that is suddenly holding little charge, check the Tesla app for a recall notification and contact your installer about the free replacement. Don't try to recharge or reset around it.
First, find out where the energy went
Your app's history is the best tool you have. Tesla's owner manual says its app shows energy consumption history and the relative amounts of energy that came from solar, the grid and the Powerwall. Enphase and Sungrow apps offer similar views. Look at the hours when the charge fell:
- Was the house using power? A steady few hundred watts all night adds up. Appliances that run overnight, such as fridges, freezers, pumps, network equipment, heating or cooling on timers and electric hot water, draw from the battery once the solar has stopped. Enphase describes the battery's job as storing energy for later use such as night-time, so a steady overnight decline is the battery doing its job.
- Was there a VPP event? The Clean Energy Regulator says a battery in a virtual power plant can release stored energy during high-demand periods. The NSW Government's battery guide adds that VPP membership means your battery will occasionally be discharged as the grid needs. The VPP operator's app or emails usually show when this happened.
- Is there a time-based schedule? Batteries set up for a time-of-use tariff, such as Enphase's Savings profile, put their discharge into your peak window, so less may be left later in the night.
- Was there an outage? In a blackout, a backup-enabled battery runs the backed-up circuits and can use its reserve. Enphase explains that the reserve is held back for exactly this.
If the history shows the battery discharging into the house, the charge isn't being "lost". The question becomes whether the battery is big enough for your overnight use, which the battery size calculator can help you think through.
The percentage is an estimate
The percentage in your app is calculated, not measured. BYD's service guideline for the Battery-Box explains that the state of charge of a lithium iron phosphate (LFP) battery can't be measured directly. It is worked out mainly from voltage, with temperature, current flow and charging behaviour also playing a part. The estimate is more accurate when the battery regularly goes through full cycles, and a correction or calibration happens every now and then.
That correction can look like a sudden jump. Sungrow's battery manual says an occasional jump in state of charge is normal and doesn't affect operation, but that frequent jumps should be raised with the installer or manufacturer. Sungrow's inverter manual also recommends fully charging the battery every 15 days if it hasn't been used or fully charged for a long time. Ask your installer how that is set up on your system. Enphase's IQ System Controller 3 INT shows a flashing yellow light while the system is performing state of charge recovery.
A brand-new battery may also show a placeholder figure at first. BYD notes that a new control unit can display a provisional percentage that corrects itself gradually once the battery starts cycling, with calibration complete after a full cycle at the latest.
Common patterns at a glance
| What you see | Likely cause | What you can check | When to call your installer |
|---|---|---|---|
| Steady drop through the night | House loads | App history of home use | Only if home use doesn't explain it |
| Sharp drop over an hour or two | VPP event or peak-time schedule | VPP app, emails and battery schedule | If you didn't agree to the event |
| Percentage jumps near full or empty | State of charge recalibration | When the jump happened | If jumps are frequent |
| Battery hits its lowest level, then charges from the grid | Low-charge protection | Charge level and grid import at that time | If it happens often |
| Charge falls with no load and no event | Possible fault or metering issue | Alerts and lights | Yes, with screenshots |
| Powerwall 2 holding almost nothing | Recall remote discharge | Tesla app notification | Contact your installer to arrange the replacement |
| Usable capacity seems smaller than it used to | Normal ageing, or a capacity problem | Compare full-to-empty energy over a few days | If the loss seems faster than the warranty allows |
It drops to the bottom, then charges from the grid
A deeply discharged battery may top itself up from the grid to protect the cells. Sungrow's hybrid inverter starts an emergency charge when the battery falls to 2% or below by default. Sungrow's battery manual also says that if a battery won't charge and its charge falls below 3%, it should be switched off and the installer or manufacturer contacted. If you're in that situation, call your installer and ask them to guide you; don't improvise a shutdown.
The battery seems smaller than it used to
All batteries lose some capacity with age. The NSW Government's guide to owning a battery calls this a normal process that can't be avoided, and notes that many manufacturers guarantee around 70% of original capacity after 10 years. Tesla's Australian Powerwall warranty, for example, states 70% energy retention at 10 years for solar self-consumption, time-based control and backup use. Warranties express this in different ways, including years, cycles and energy throughput.
Temperature matters too. Tesla says Powerwall may limit charge and discharge power at the extremes of its temperature range. The NSW guide describes the operating temperature range as the range where a battery works without changes to power output or capacity, so a cold night or a heatwave can affect what you see.
If you think the battery has lost more capacity than the warranty allows, record how much energy it delivers from full to empty on a few quiet nights. Then raise it with your installer, using our warranty claims guide.
Charge falls with no load and no event
If the history shows no home use, no VPP event and no schedule, yet the charge keeps dropping, that needs investigating. The cause could be a metering or sensor problem, a communication fault or a battery fault. Check the battery's light and any alerts, and note them using our error codes guide. Don't open the unit or touch its wiring; the Clean Energy Regulator tells owners never to touch wiring or electrical components.
When to call your installer or manufacturer for help
Call your installer if the charge drops with no load or event to explain it, or if state of charge jumps happen often. Also call if the battery keeps falling to its minimum and charging from the grid, or if capacity seems to be fading quickly. Have ready:
- screenshots of the app's state of charge and energy history for at least two or three nights
- details of any VPP, retailer plan or schedule you're on
- the model and serial numbers, firmware version if the app shows it, and any alerts
- notes on the weather, especially very hot or cold nights
Your installer is the first contact; brand-specific steps are in our guides for Tesla Powerwall, BYD Battery-Box, Sungrow and Enphase IQ Battery. The ACCC says consumer guarantees apply to home batteries alongside the manufacturer's warranty.
FAQ
How much charge should a battery lose overnight if nothing is on?
There is rarely truly "nothing" on. Fridges, network gear and standby loads keep drawing power. Check the app's home use for those hours before assuming the battery is leaking charge.
Why did my battery jump from 30% to 10%?
That is often the system correcting its state of charge estimate, which BYD and Sungrow both describe. If it happens often, tell your installer.
Is losing capacity over the years covered by warranty?
Some loss is expected. Many warranties guarantee a minimum share of the original capacity after a set period, such as 70% after 10 years. Check the figure and conditions in your warranty.
Sources
- Powerwall 2 recall, PRA 2025/20611 (ACCC Product Safety Australia, accessed November 2026)
- Powerwall 2 Owner's Manual: Monitoring Your System (Tesla owner manual, Australian edition, accessed November 2026)
- Powerwall 2 Owner's Manual: Care and Maintenance (Tesla owner manual, Australian edition, accessed November 2026)
- Tesla Powerwall Warranty (Australia and New Zealand), Rev. 1.17 (Tesla warranty, accessed November 2026)
- Enphase Energy System with IQ Battery 5P Owner's Guide (Enphase owner's guide, Australian site, accessed November 2026)
- BYD Battery-Box Premium HVS&HVM Service Guideline and Checklist for BCU-V2.0 (BYD service guideline, accessed November 2026)
- High Voltage LFP Battery SBR064/096/128/160/192/224/256 User Manual (Sungrow battery manual, accessed November 2026)
- 1-phase Hybrid Inverter SH3.0RS to SH6.0RS-20 User Manual (Sungrow inverter manual, accessed November 2026)
- Virtual power plants (Clean Energy Regulator, accessed November 2026)
- Solar batteries (Clean Energy Regulator, accessed November 2026)
- Guide to owning a battery (NSW Climate and Energy Action, accessed November 2026)
- Solar panel systems and home batteries (ACCC consumer guidance, accessed November 2026)