If your battery still has charge but the house keeps drawing from the grid after sunset, the cause is usually one of four things: the battery has reached the reserve level it must keep for outages, a mode or schedule is telling it to wait, the house is drawing more power than the battery can supply at once, or a fault has stopped it talking to the inverter or gateway. A small, steady trickle of grid power can also be normal. Check the app's reserve and mode settings first, then compare the battery's output with the house load at the time, then look for alerts.
Safety first
None of the checks below involve opening anything or working in the switchboard. Stick to what the app and the unit's lights show you. If the battery is idle and also hot to the touch, smells of burning or chemicals, is swollen, leaking, hissing or popping, treat it as a safety issue and follow our warning signs guide. Call 000 if there is smoke or fire.
Tesla warns owners not to disconnect anything from, or add anything to, a Powerwall, and not to operate it with covers removed. Enphase says only qualified electricians should troubleshoot or replace its equipment or wiring. Repeatedly switching a battery off and on to "wake it up" can hide the real problem, so note what you see and pass it on instead.
Some grid import at night is normal
While the grid is connected, the battery works alongside it rather than replacing it. Enphase's owner's guide, for example, lists grid import as the last source the home draws on, after solar and the battery. Sungrow's hybrid inverter manual says the system starts discharging the battery once grid import goes above a 70 W threshold, so a small amount of import can appear in the app even when the battery is working normally.
Every battery also has a limit on how much power it can deliver at once. Sungrow says discharge power is capped by the lower of the inverter's and the battery's maximum current, so it may not reach the battery's nominal rating. Enphase sells the IQ Battery 5P in Australia in several output settings so it can meet local network rules, and all batteries in a system are set to the same rating. When the oven, a heat pump and an air conditioner run together, the grid supplies whatever the battery can't.
If you regularly run out of battery well before morning, the battery may be small for your evening use. The battery size calculator gives you a starting point before you talk to an installer about adding capacity.
Check the reserve and the lower charge limit
Most batteries hold back part of their charge. Enphase calls it reserve capacity: if the reserve is set to 30%, the IQ Batteries won't discharge below 30% unless there is a grid outage. Sungrow's battery manual explains that once the charge reaches the lower limit set in the hybrid inverter, the battery stops discharging. Its app also has a backup mode where you set a reserved charge for outages, which becomes the minimum level while the grid is on.
So a battery sitting at, say, 20% all night may be exactly where it was told to stop. Enphase lets owners change the reserve from the battery storage page of the Enphase App. Sungrow says its charge limits are changed in iSolarCloud by qualified personnel. If you're not sure which settings you are allowed to change, ask your installer before adjusting anything.
Check the mode, profile or schedule
The battery's operating mode decides when it discharges.
- Full backup modes hold the battery for outages. Enphase says that in its Full Backup profile the whole battery capacity is kept in reserve for a power outage, so the home runs on solar and grid while the grid is up.
- Storm features can switch modes for you. Enphase's Storm Guard moves the system to Full Backup when severe weather is detected, then switches back afterwards. Tesla's troubleshooting notes describe grid charging during a Storm Watch weather alert as expected.
- Time-of-use modes wait for peak periods. In Enphase's Savings profile the battery discharges during peak hours. Where the export tariff is equal to or higher than the import tariff, the battery powers the home and the solar is exported. Outside the peak window, the Savings profile puts charging from solar first and uses the grid when solar falls short.
- Schedules and plans. The NSW Government's battery guide suggests setting a battery to discharge through the evening peak, typically 4pm to 8pm. If your schedule ends at 8pm, grid use after that may be expected.
If you changed electricity plans recently, check that the battery's tariff or schedule settings still match the new plan.
Common causes at a glance
| Symptom | Likely cause | What you can check | When to call your installer |
|---|---|---|---|
| Small grid import even while discharging | Normal response to changing load | Size of the import in the app | If import stays large while the battery shows idle |
| Battery stops at the same percentage each night | Reserve or lower limit reached | Reserve setting in the app | If it stops well above any setting you know about |
| Battery idle all evening with plenty of charge | Backup or storm mode, or a time window | Mode, profile and storm alerts | If the mode is correct but it still won't discharge |
| Grid import rises when big appliances start | Load exceeds the battery's output | Live load against battery output | Only if output seems low for your model |
| Battery idle and an alert or red light shows | Fault or lost communication | Error code and light colour | Straight away |
| Discharge on nights you didn't expect | VPP or retailer event | VPP app or emails | If you didn't agree to it |
The battery has charge but stays idle
Rule out the mode and reserve first. If neither explains it, the battery may have lost contact with the device that controls it. Enphase says that if the IQ Gateway is unpowered or has failed, the IQ Battery 5P won't discharge while the grid is on. BYD's service guideline says a Battery-Box shuts down automatically within 30 minutes if it loses communication with the inverter. Sungrow's battery manual suggests checking for fault codes and acting on them, then contacting the installer if the battery still won't discharge.
Check the battery's light. On a Powerwall 2, a fading light means it is charging or discharging, and a flashing light means a fault. On Powerwall 3, solid white is normal operation and flashing red is an inverter fault. On an Enphase IQ Battery 5P, a soft blue pulse means discharging, and a red double flash means an error that Enphase support needs to look at. Our error codes guide explains how to record what you see.
The app shows grid import even while the battery is discharging
The battery decides how much to discharge using meters or current sensors (CTs) on your main cables. If a sensor faces the wrong way or sits on the wrong circuit, the system can misread the power flows. Sungrow lists alarms for a meter or CT connected in reverse and for lost meter communication. Tesla's installer notes include checks for CT direction and placement. These are electrical jobs for your installer, so note the alarm and the times you saw it.
Hot nights and heatwaves
Batteries limit output when they get too hot. Tesla says Powerwall may limit discharge power at the extremes of its temperature range, and Powerwall 3 output may be reduced above 40°C. Sungrow's battery manual lists ambient temperatures above 55°C as a reason discharge can stop. What you can do is keep the area around the unit clear so air can move; anything beyond that is for your installer.
Virtual power plant and retailer events
If you've joined a virtual power plant (VPP), the operator can use your battery to support the grid. The Clean Energy Regulator says a VPP battery can release stored energy during high-demand periods, and the NSW guide notes your battery will occasionally be discharged as the grid needs. That can leave less in the battery for your own evening use. The details depend on your contract with the VPP operator, so check its app or emails before assuming a fault.
When to call your installer or the manufacturer
Call your installer if the battery has charge above its reserve, the mode is right, there is no VPP event, and it still won't discharge. Also call if you see any fault code, a red or flashing fault light, or a sensor alarm. Have ready:
- screenshots showing the state of charge, reserve setting, mode and grid import at the time
- the model and serial numbers of the battery and inverter
- any alert text or code, and the light colour or pattern
- the date it started, and any recent change such as a new plan, VPP sign-up, firmware update or electrical work
Start with the installer or retailer. Brand-specific checks are in our guides for Tesla Powerwall, Enphase IQ Battery, Sungrow and BYD Battery-Box. If the battery turns out to be faulty, your consumer guarantee rights under the Australian Consumer Law apply on top of the manufacturer's warranty, as the ACCC explains. See our warranty claims guide for the steps.
FAQ
Why is my battery at 20% and not being used?
That is often the reserve or lower limit doing its job. Check the reserve setting in your app. If it is set lower than where the battery stops, ask your installer to check the lower limit in the inverter.
Does a bigger reserve help in a blackout?
Yes, a higher reserve keeps more energy for an outage, but it leaves less for everyday evening use. It is a trade-off you can discuss with your installer, and only works if your system is set up for backup. See backup not working in a blackout.
Why does the battery discharge in the afternoon instead of at night?
Check for a VPP event or a time-of-use setting whose peak window starts in the afternoon. In Enphase's Savings profile, for example, the battery powers the home during peak hours, and when the export tariff is at least as high as the import tariff the solar is exported instead.
Sources
- Enphase Energy System with IQ Battery 5P Owner's Guide (Enphase owner's guide, Australian site, accessed November 2026)
- 1-phase Hybrid Inverter SH3.0RS to SH6.0RS-20 User Manual (Sungrow inverter manual, accessed November 2026)
- High Voltage LFP Battery SBR064/096/128/160/192/224/256 User Manual (Sungrow battery manual, accessed November 2026)
- Powerwall 2 Owner's Manual: System Operation (Tesla owner manual, Australian edition, accessed November 2026)
- Powerwall 2 Owner's Manual: Troubleshooting (Tesla owner manual, Australian edition, accessed November 2026)
- Powerwall 3 Owner's Manual: Troubleshooting (Tesla owner manual, EMEA/APAC edition, accessed November 2026)
- Powerwall 3 Owner's Manual: Care and Maintenance (Tesla owner manual, EMEA/APAC edition, accessed November 2026)
- Powerwall / Powerwall+ is Charging from Grid Rather than Available Solar (Tesla installer troubleshooting manual, accessed November 2026)
- BYD Battery-Box Premium HVS&HVM Service Guideline and Checklist for BCU-V2.0 (BYD service guideline, accessed November 2026)
- Virtual power plants (Clean Energy Regulator, accessed November 2026)
- Residential batteries (NSW Climate and Energy Action, accessed November 2026)
- Guide to owning a battery (NSW Climate and Energy Action, accessed November 2026)
- Solar panel systems and home batteries (ACCC consumer guidance, accessed November 2026)